Codesys Elevator Project -

IF NOT movingUp AND NOT movingDown AND NOT doorOpen THEN // Idle – look for any pending calls FOR i := 1 TO N DO IF carCall[i] OR callUp[i] OR callDown[i] THEN targetFloor := i; IF i > currentFloor THEN movingUp := TRUE; ELSIF i < currentFloor THEN movingDown := TRUE; ELSE doorOpen := TRUE; // already there ENDIF; EXIT; ENDIF; ENDFOR; END_IF DoorTimer(IN:= doorOpen OR doorCloseRequest, PT:= T#3s); IF DoorTimer.Q THEN doorOpen := FALSE; // after doors close, re-evaluate next target END_IF d. Safety Interlock In any real elevator project, you’ll see:

❌ – Sensor flicker triggers multiple stops. ✅ Use TON or R_TRIG to confirm floor arrival for >20ms. codesys elevator project